The following table outlines the different regions and geographies where each Impinj reader is certified. [Note 1]
Approved Reader Part Numbers | |||||
---|---|---|---|---|---|
Region | R120 (1-port) | R220 (2-port) | R420 (4-port) | R700 (4-port) | R720 (4-port) |
Australia | N/A | N/A | GX3 | 341 | N/A |
Brazil | N/A | GX1 | GX1 | 341 | N/A |
Canada | USA | USA | USA | 141, 341 | 343 |
China | GX2 | GX2 | GX2 | 341 | N/A |
European Union | EU1 | EU1 | EU1 (865-868 MHz) EU2 (915-921 MHz) [Note 2] |
241 | 243 |
Hong Kong | N/A | GX1 | GX1 | 341 | N/A |
India [Note 3] | EU1 | EU1 | EU1 | 241 | N/A |
Indonesia | N/A | N/A | GX1 | 341 | N/A |
Japan | N/A | N/A | JP2 | 441 | N/A |
Malaysia | N/A | GX1 | GX1 | 341 | N/A |
Mexico | N/A | USA | USA | 341 | N/A |
Morocco [Note 5] | N/A | N/A | EU1 | N/A | N/A |
New Zealand | N/A | GX1 | GX1 | 341 | N/A |
Philippines | N/A | N/A | GX1 | 341 | N/A |
Saudi Arabia | EU1 | N/A | EU1 | 241 | N/A |
Singapore [Note 4] | N/A | N/A | GX1 | 341 | N/A |
South Africa | GX2 | GX2 | GX2 | 341 | N/A |
South Korea | N/A | N/A | GX2 | 341 | N/A |
Taiwan | N/A | GX1 | GX1 | 341 | N/A |
Thailand | N/A | N/A | GX1 | 341 | N/A |
UAE | N/A | N/A | EU1 | 241 | N/A |
Uruguay | N/A | GX1 | GX1 | 341 | N/A |
USA (FCC) | USA | USA | USA | 141, 341 | 343 |
Vietnam [Note 4] | N/A | N/A | GX1 | 341 | N/A |
Note 1: Subject to change. Certification means having a LLRP region identification number and a regulatory certificate where required. Regulatory certification is voluntary in some countries. N/A indicates there is no certification for that device and therefore this product cannot be used in that region.
Note 2: Conforms with Article 3.1(b) of EN 301 489-3 v2.1.1 and Article 3.2 of EN 302 208 v3.3.0 Draft 2020-05. Visit this page for more details about the acceptance of this new standard by specific EU countries.
Note 3: Must be purchased from authorized India distributor.
Note 4: Users are required to obtain a license for each use case where the radiated power during operation is between 500mW and 2000mW. Contact the local regulatory authority to obtain a license.
Note 5: Download and install this upg file to enable the Morocco region.
To ensure regulatory compliance, professional installers / integrators must follow the transmit power setting instructions provided in the Installation and Operations Guide. Impinj recommends readers should be used with the antennas listed in Appendix A of the Installation and Operations Guide or with antenna(s) of the same type with equal or less gain. RFID Integrators should contact the regulatory agency in the country where equipment is to be used to determine if their RFID system requires any additional testing/certification.
The following table outlines the different regions and geographies where each Impinj gateway is certified. [Note 1]
Approved Gateway Part Numbers | |||
---|---|---|---|
Region | R640 (xPortal) | R660 (xSpan) | R680 (xArray) |
Australia | GX3 | GX3 | GX3 |
Brazil | GX1 [Note 6] | GX1 | GX1 |
Canada | FCC | USA | USA |
China | N/A | GX2 | GX2 |
European Union | EU1 | EU1 (865-868 MHz) EU2 (915-921 MHz) [Note 2] |
EU1 (865-868 MHz) EU2 (915-921 MHz) [Note 2] |
Hong Kong | GX1 | GX1 | N/A |
India [Note 3] | N/A | EU1 | EU1 |
Japan | N/A | JP2 | JP2 |
Malaysia | GX1 | N/A | N/A |
Mexico | FCC | USA | USA |
New Zealand | GX1 | GX1 | N/A |
Philippines | N/A | N/A | N/A |
Saudi Arabia | N/A | EU1 | EU1 |
Singapore [Note 4] | N/A | GX1 | GX1 |
South Africa | GX2 | GX2 | GX2 |
South Korea | GX2 | GX2 [Note 7] | GX2 |
Taiwan | GX1 | GX1 | GX1 |
Thailand | GX1 | GX1 | N/A |
UAE | N/A | EU1 | N/A |
Uruguay | N/A | N/A | N/A |
USA (FCC) | FCC | USA | USA |
Vietnam | N/A | N/A | N/A |
Note 1: Subject to change. Certification means having a LLRP region identification number and a regulatory certificate where required. Regulatory certification is voluntary in some countries. N/A indicates there is no certification for that device and therefore this product cannot be used in that region.
Note 2: Conforms with Article 3.1(b) of EN 301 489-3 v2.1.1 and Article 3.2 of EN 302 208 v3.3.0 Draft 2020-05. Visit this page for more details about the acceptance of this new standard by specific EU countries.
Note 3: Must be purchased from authorized India distributor.
Note 4: Users are required to obtain a license for each use case where the radiated power during operation is between 500mW and 2000mW. Contact the local regulatory authority to obtain a license.
Note 6: Impinj xPortal regulatory certificate for Brazil will expire on November 30, 2020 and will not be renewed. Please visit this Product Change Notice for more details.
Note 7: Download and install this upg file to enable the South Korea region on the xSpan.
To ensure regulatory compliance, professional installers / integrators must follow the transmit power setting instructions provided in the Installation and Operations Guide. Impinj recommends readers should be used with the antennas listed in Appendix A of the Installation and Operations Guide or with antenna(s) of the same type with equal or less gain. RFID Integrators should contact the regulatory agency in the country where equipment is to be used to determine if their RFID system requires any additional testing/certification.
Comments
Supported Regions table has been updated. We have added xSpan support for Brazil, China, Hong Kong, Malaysia, Singapore, Taiwan and UAE.
Supported Regions table has been updated. We have added R220/R420/R640 support for Malaysia.
Supported Regions table has been updated. We have added R420 support for Vietnam.
Supported Regions table has been updated. We have added R120 and R220 support for UAE.
Supported Regions table has been updated. We have added R120 support for India.
Supported Regions table has been updated. We have added R120 support for South Africa.
Supported Regions table has been updated. We have added R120/R420/R680 support for Saudi Arabia.
Supported Regions table has been updated. We have added xSpan support for Saudi Arabia.
Supported Regions table has been updated. We have added R420/R660/R680 support for the European Union ETSI upper band (915-921 MHz).
Supported Regions table has been updated. We have added Impinj R700 support for USA (FCC) and Canada.
Supported Regions table has been updated. We have removed support for R640 (xPortal) in China.
Supported Regions table has been updated. We have added Impinj R700 support for the European Union.
Supported Regions table has been updated. We have added R420 support for Indonesia and Morocco. Note: Octane firmware version 6.4 or 7.0 are required.
Impinj xPortal regulatory certificate for Brazil will expire on November 30, 2020 and will not be renewed. See Note 6 above for additional details.
Supported Regions table has been updated. We have added support for the new Impinj R700 global reader model (IPJ-R700-341) that includes support for USA (902 – 928 MHz) and countries that utilize parts of this band.
Supported Regions table has been updated. The Impinj R700 global reader model (IPJ-R700-341) now includes support for Australia, Brazil, Hong Kong, New Zealand, Philippines, Thailand and Uruguay. Firmware version 7.4 is required.
Supported Regions table has been updated. The Impinj R700 global reader model (IPJ-R700-341) now includes support for South Korea and Vietnam. A new Impinj R700 model (IPJ-R700-441) is now available for Japan. Firmware version 7.4.1 is required.
Supported Regions table has been updated. The Impinj R700 global reader model (IPJ-R700-341) now includes support for Indonesia, Malaysia, Singapore and Taiwan. The Impinj R700 model (IPJ-R700-241) now includes support for Saudi Arabia and UAE. Firmware version 7.5.0 is required.
Supported Regions table has been updated. The Impinj R700 global reader model (IPJ-R700-341) now includes support for China. Firmware version 7.5.0 is required.
Supported Regions table has been updated. We have added xSpan support for China.
Supported Regions table has been updated. The Impinj R700 global reader model (IPJ-R700-341) now includes support for South Africa. India is now supported on IPJ-R700-241. Firmware version 7.6.0 is required.
Supported Regions table has been updated. We have removed support for R120 and R220 in UAE.
Supported Regions table has been updated. We have added xSpan support for South Korea.
Article is closed for comments.